WTB4SLC-3P2262A00

7,860,000

Tên sản phẩm: Miniature photoelectric sensors W4SL-3

Danh mục: Photoelectric sensors

Model: WTB4SLC-3P2262A00

ID: 1080939

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1080939 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 25 mm … 300 mm 1)
Sensing range 25 mm … 300 mm 1)
Type of light Visible red light
Light source Laser 2)
Light spot size (distance) ? 1 mm (170 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment

Cable

Single teach-in button

Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output
Special applications Detecting small objects
    1) Object with 90 % reflectance (referred to standard white, DIN 5033).2) Average service life: 50,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Power consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ? 100 mA
Response time ? 0.5 ms 5)
Response time Q/ on Pin 2 300 ?s … 450 ?s 5) 6)
Switching frequency ? 1,000 Hz 7)
Switching frequency Q / to pin 2 1,000 Hz 8)
Connection type Male connector M8, 4-pin
Circuit protection

A 9)

B 10)

C 11)

Protection class III
Weight 100 g
IO-Link ?
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

Ambient operating temperature ?10 ?C … +50 ?C
Ambient operating temperature extended ?30 ?C … +55 ?C 12) 13)
Ambient storage temperature ?30 ?C … +70 ?C
MTTFd: mean time to dangerous failure 424 years (EN ISO 13849-1) 14)
Repeatability Q/ on Pin 2: 150 ?s 6)
    1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) Q = light switching.5) Signal transit time with resistive load.6) Valid for Q on Pin2, if configured with software.7) With light/dark ratio 1:1.8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.9) A = VS connections reverse-polarity protected.10) B = inputs and output reverse-polarity protected.11) C = interference suppression.12) As of Ta = 50 ?C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.13) Operation below Tu ?10 ?C is possible if the sensor is already switched on at Tu > ?10 ?C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu ?10 ?C is not permissible.14) Mode of calculation: Parts-Count-calculation.
Classifications
ECl@ss 5.0 27270904
ECl@ss 5.1.4 27270904
ECl@ss 6.0 27270904
ECl@ss 6.2 27270904
ECl@ss 7.0 27270904
ECl@ss 8.0 27270904
ECl@ss 8.1 27270904
ECl@ss 9.0 27270904
ETIM 5.0 EC002719
ETIM 6.0 EC002719
UNSPSC 16.0901 39121528
Smart Task
Smart Task name Base logics
Logic function

Direct

AND

OR

WINDOW

Hysteresis

Timer function

Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Switching frequency

SIO Direct: 1000 Hz 1)

SIO Logic: 600 Hz 2)

IOL: 450 Hz 3)

Response time

SIO Direct: 300 ?s … 450 ?s 1)

SIO Logic: 750 ?s … 900 ?s 2)

IOL: 800 ?s … 1000 ?s 3)

Repeatability

SIO Direct: 150 ?s 1)

SIO Logic: 150 ?s 2)

IOL: 400 ?s 3)

Switching signal QL1 Switching output
Switching signal QL2 Switching output
    1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure

Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = empty