WTT190L-N3536

7,509,000

Tên sản phẩm: MultiTask photoelectric sensors PowerProx

Danh mục: Photoelectric sensors

Model: WTT190L-N3536

ID: 6055964

Nhà sản xuất: SICK

Xuất xứ: JP

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 6055964 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 17.6 mm x 46.5 mm x 34.1 mm
Housing design (light emission) Rectangular
Sensing range max. 200 mm … 2,500 mm 1)
Sensing range 200 mm … 2,500 mm 2)
Type of light Visible red light
Light source Laser 3)
Light spot size (distance) ? 10 mm (2,500 mm)
Wave length 658 nm
Laser class 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment Potentiometer, 4 turns (2 x)
    1) Object with 6 … 90 % remission (based on standard white to DIN 5033).2) Adjustable.3) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple ? 5 Vpp 2)
Power consumption 75 mA 3)
Switching output NPN 4)
Number of switching outputs 2 (Q1, Q2) 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via light/dark selector
Output current Imax. ? 100 mA
Response time ? 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Analog output
Input Sender off
Connection type Cable with plug M12, 5-pin, 0.3 m 7)
Cable material PVC
Conductor cross-section 0.14 mm?
Circuit protection

A 8)

B 9)

C 10)

Protection class III
Weight 45 g
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied BEF-W190 mounting bracket
Ambient operating temperature ?10 ?C … +50 ?C
Ambient storage temperature ?40 ?C … +70 ?C
Warm-up time < 5 min 11)
Initialization time < 300 ms
UL File No. NRKH2.E300503
    1) Limit values. Operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load. At VS = 24 V.4) Q1, Q2 = 2 switching thresholds, light/dark switching selectable via light/dark selector.5) Signal transit time with resistive load.6) With light/dark ratio 1:1.7) Do not bend below 0 ?C.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) For best performance consider warm up time ? 5 minutes.
Classifications
ECl@ss 5.0 27270904
ECl@ss 5.1.4 27270904
ECl@ss 6.0 27270904
ECl@ss 6.2 27270904
ECl@ss 7.0 27270904
ECl@ss 8.0 27270904
ECl@ss 8.1 27270904
ECl@ss 9.0 27270904
ETIM 5.0 EC002719
ETIM 6.0 EC002719
UNSPSC 16.0901 39121528