GH Series 350 Bar

GH Series 350 Bar

      Features:

 

      • Optimised flow rates and compact filter housing.

 

      • Improved housing design with double O-ring sealing.

 

      • Threaded rod element fixing.

 

      • Pleated elements.

 

      • Complete filter including filter element and manual drain.

 

      • As an option filters are also available without drain.

 

        • All filter sizes offer connectors for the installation of calibrated differential pressure gauges.

 

Product Description

ELEMENT CHANGE INTERVAL

12 months for V, ZP and XP elements / 3 months or max. 1500 hours of operation for A elements

FILTRATION EFFICIENCY

99.99% to 99.99999%, depending on filter type

RESIDUAL OIL CONTENT

0.01 mg/m³ @ 20 °C (XP), 0.5 mg/m³ @ 20 °C (ZP), n.a. (V), 0.003 mg/m³ @ 20 °C (A)

MAXIMUM FLOW RATE (M³/H)

365 @ 350 bar(g) to 4261 @ 350 bar(g)

MAXIMUM FLOW RATE (CFM)

214 @ 5076 psig to 2507 @ 5076 psig

MAXIMUM OPERATING PRESSURE (BARG)

350

MAXIMUM OPERATING PRESSURE (PSIG)

5076

MAXIMUM OPERATING TEMPERATURE (F)

176 or 104 for filters with activated carbon elements

MINIMUM OPERATING TEMPERATURE (C)

1.5

MINIMUM OPERATING TEMPERATURE (F)

34.7

MATERIALS OF CONSTRUCTION

Housing: Aluminum, anodized / Seals: NBR (G3 – G7), Housing: Steel / Seals: NBR (G9 – G13)

WEIGHT (KG)

2.8, 3.4, 18.2, 21.9, 28.3, 39.2

WEIGHT (LBS)

6.17, 7.49, 40.12, 48.28, 62.39, 86.42

WIDTH (MM)

80, 116, 125

WIDTH (INCH)

3.15, 4.56, 4.92

HEIGHT (MM)

355, 232, 420, 297, 455, 332, 540, 417, 655, 532, 910, 787

HEIGHT (INCH)

13.97, 9.13, 16.53, 11.69, 17.91, 13.07, 21.26, 16.42, 25.78, 20.94, 35.82, 30.98

CONNECTION TYPE

BSP-P (DIN ISO 228)

MICRON RATING (ΜM)

0.01, 1, 3, n.a., depending on filter type

DRAIN PORT SIZE

G1/4i

BRAND

Parker domnick hunter

PRE-TREATMENT REQUIREMENT

depending on filter type

CERTIFICATIONS

PED Fluid Group II, TR

APPLICATION TYPE

Filtration of compressed air and gaseous Nitrogen